The Klein Tools ET450 Advanced Circuit Tracer Kit is a professional tracer for energized and non-energized breakers, fuses and wires. When the Transmitter is connected to a circuit, the Receiver's sensitivity can easily be adjusted to detect the transmitted signal on breakers, fuses and wire through drywall, cement block and underground. Kit comes with transmitter, receiver, blade and ground prongs, alligator clips, 3 ft. and 20 ft. lead adapters, AC plug leads, instructions, all required batteries and a hard carrying case with handle for convenient transportation and storage.
Product Depth (in.) | 16.12 in |
|---|---|
Product Width (in.) | 12.75 in |
Features | Audible Alert |
|---|---|
Functions Measured | Circuit Breaker Detection |
Included | Batteries, Case, Test Leads |
Number of Pieces | 1 |
Power Source | Battery Operated |
Returnable | 90-Day |
Test Meter Type | Multimeter |
Certifications and Listings | No Certifications or Listings |
|---|---|
Manufacturer Warranty | Please refer to the attached warranty document in the Product Overview section above under Info & Guides |
The ET450 is designed to trace energized wires up to 480V. For more information please see the Use and Care Manual under Additional Resources From the Manufacturer or contact Klein Tools Customer Service 1-800-553-4676
The ET450 will detect about 2 ft. depth, but will vary based on the type of material.
It will detect about 2 ft. depth, but will vary based on the type of material.
For full instructions please see the Use and Care Manual under Additional Resources From the Manufacturer. Circuit Breaker Finder (energized and de-energized) 1. Connect the Transmitter to the circuit to be identified using either the direct ground or remote ground connection and power the Transmitter on. The direct ground and remote ground connection methods can be used on both energized and de-energized circuits, but an energized circuit produces a higher signal strength. 2. Verify that the Energized Indicator on the Transmitter is illuminated if connected to a circuit with voltage above 25V AC/DC and is not illuminated for de-energized circuits. 3. Go to the electrical panel and power on the Receiver. If there is more than one panel, touch the tip of the Receiver to each panel cover to identify the panel with the highest signal level. Use the Increase Sensitivity and Decrease Sensitivity buttons to adjust the Receiver sensitivity level to identify the panel with the highest reading. 4. Once the panel has been identified, open the cover. 5. Orient the Receiver facing left or right and perpendicular to the breakers (See below). Slowly move the Receiver up and down in front of each breaker. Use the Increase Sensitivity and decrease Sensitivity buttons to adjust the Receiver sensitivity levels as needed to locate the breaker with the highest reading. After any sensitivity level changes, rescan all the breakers to find the breaker with the highest reading.
Yes
The ET450 does not detect bootleg grounds.
Yes, the kit can trace DC circuits and breakers
Up to 480V AC/DC