Enhancing the installation process, the Romex Type NM-B Copper Building Wire is equipped with a patented SIMpull Cable Jacket, ensuring effortless pulling, stripping, and overall ease of use. A staple in residential building wiring, this cable serves as a reliable branch circuit for switches and outlets. Its application is restricted to above-ground installation within dry environments, and it offers a notable voltage rating of 600-volts, guaranteeing steadfast performance. Noteworthy is its versatility, as the NM-B cable can be safely threaded through air voids in masonry block or tile walls, granted these surfaces remain free from moisture. Proudly exemplifying its origin, this cable proudly bears the distinction of being Made in America, reflecting a commitment to quality craftsmanship.
Total Wire Length (ft.): 125 ft
Total Wire Length (ft.) | 125 ft |
|---|
Commercial/Residential | Residential |
|---|---|
Conductor Material | Copper |
Features | Heat Resistant, Jacketed |
Gauge | 8 |
Grounded | Grounded |
Indoor/Outdoor | Indoor |
Jacket Color | Black |
Max Amps | 40 |
Number of Conductors | 2 |
Returnable | 90-Day |
Stranded or Solid | Stranded |
Voltage (v) | 600v |
Wet Location Use | Dry |
Wire Cut Type | Pre-Cut Length |
Certifications and Listings | UL Listed |
|---|
Hello, thank you for your question. This answer will require a more technical response. Please reach out to our technical team at cableteachsupport@southwire.com for a detailed explanation of your question.
No red wire. Just black, white & bare ground wire. You could use the white wire as red for 2-hot & one ground wire.
Hi there, and thanks for reaching out! We'd like to hear more about your question, so that we can ensure that we're providing the most accurate answer. Please reach out to our dedicated team at consumersupport@southwire.com and we'll be happy to help.
This wire is rated for 40 amps and 600 volts. A Miller 251 welder can draw significantly more than 40 amps, especially at higher output settings. Using this wire for a Miller 251 could lead to overheating and potential fire hazards. You should consult a qualified electrician to determine the correct wire size and type for your welder and specific application. They can help ensure your setup is safe and meets code requirements.
No. Conduit outdoors will still get wet inside due to condensation. This wire is rated for dry use only.
you have to use 8/3 or 10/3. If the circuit is less than 100 feet long you can go with 10/3 if nothing else on that circuit.
No, you don't have to buy the whole 125ft. This 8/2 Romex SIMpull wire is sold as a 125ft roll, but you can cut it to the desired length for your project.